Tender Details
Request For Tender - Cairns Jockey Club - Design and Construct Machinery Shed
Business Name
Racing Queensland
VP Reference #
VP483514
Buyers Reference #
RQ03814
Opens
Monday 20 October 2025
(E. Australia Standard Time)
Closes
Friday 14 November 2025 02:00 PM
(E. Australia Standard Time)
CLOSED
Supplier query cut-off
Monday 10 November 2025 02:00 PM
(E. Australia Standard Time)
Expected decision
Friday 26 December 2025
(E. Australia Standard Time)
Buyer Details
Business Name
Racing Queensland
Location
Racecourse Rd
Deagon, Queensland 4017
Australia
WebSite:
https://www.racingqueensland.com.au/
Business Info
The Racing Queensland Board trading as Racing Queensland provides a platform to service the racing industry across the 3 codes of racing.
Racing Queensland's vision is to become the #1 sporting industry in the sunshine state, with the mission to champion great racing and events which connect Queensland communities.
Contact Details
The buyer has elected to have their personal and contact details hidden. These details will be revealed at the buyers discretion.
What the buyer is requesting
Details
Racing Queensland (RQ) is seeking offers from suitably experienced Suppliers for the provision of Design and Construction of Machinery Shed in Cairns Jockey Club.
The successful Tenderer will be engaged via Racing Queensland’s Design and Works agreement to complete the works.
The following Request For Tender documentation is available to be downloaded strictly via Vendor Panel. VendorPanel reference: VP483514
Please find attached RQ03814 conditions and documentation issued with the RFT:
• This Invitation Letter;
• Scope of Works Document
• RFT/Non-Price Response Schedule; (returnable)
• Pricing Schedule; (returnable)
• RQ’s Design and Works Agreement TEMPLATE only;
• RQ Conditions of Tendering;
• Queensland Government Supplier Code of Conduct;
• Supplier Code of Conduct Formal Declaration Form; (returnable) and
• Conflict of Interest Declaration (returnable)
Offers may only be submitted electronically through VendorPanel, no later than 2pm QLD (AEST) on Friday 14th November 2025. The closing time and date nominated in this Request For Tender is the latest time by which a submission must be logged. Late submissions will NOT be accepted.
Tenderers Interested in the Optional Site Meeting, Please RSVP by sending an email to Procurement@racingqueensland.com.au and advise number of personnel and a mobile number.
Site Meeting Details:
Date: (Thursday) 6th November 2025
Time: 11:00a.m.
Duration: 2 hours
Address: 585 – 619 Mulgrave Road, Woree QLD 4868
Please direct all Tender related questions or clarifications in writing to Racing Queensland’s Procurement Team via VendorPanel.
In addition to this opportunity, RQ is also seeking a suitably experience contractor for the Refurbishment of Existing Horse Stables at the same site (see VP483375). Interested tenderers are welcome to view and submit for both projects. *Note that submissions are to remain separate for the two projects.
Questions asked by the buyer
Question 1 - [Required]
Have you completed and submitted all returnable as outlined in the letter of invitation
Question 2 - [Required]
Have all the mandatory criteria been met for your tender to be considered conforming?
Question 3 - [Required]
Have you provided a copy of all relevant licenses and insurance?
Question 4 - [Required]
Have you read and acknowledged all clarifications, RFIs, and addenda posted for this tender?
Supplier lists selected
Lists
Building Products & Materials
Construction & Operation
Categories selected
Categories
Building Products & Materials
1: Sheds & Shelters & Shade Structures
Construction & Operation
1: Building Construction Materials & Services
Regions of Service
Locations
Queensland
1: Far North
All Regions of Service locations are within Australia.
Information requested by others
04/Nov/2025 11:17 AM
Question
:
Good Morning
Can you please confirm the below.
• What is the exact power requirement — is it limited to what’s outlined in the scope of works, or is there requirement for future expansion?
• Is there sufficient power capacity at the existing supply locations?
Thank you,
Answered on 05/Nov/2025 09:45 AM
:
Hi,
Q: What is the exact power requirement — is it limited to what’s outlined in the scope of works, or is there requirement for future expansion?
A: Due to budget restrictions, the basic electrical requirements stated in the Scope is all that is currently requested. Future expansion shall be the club’s responsibility outside of this project.
Q: Is there sufficient power capacity at the existing supply locations?
A: The club has previously advised that the existing power to the irrigation tanks and pumps will be able to supply the shed. The original power to the existing shed can also be re-directed. These power capacities are required to be confirmed by vendors.
Thanks
07/Nov/2025 07:57 AM
Question
:
Good Morning
Is it possible to obtain the measurements regarding the submains and verify the compliance?
Thanks
Answered on 10/Nov/2025 12:42 PM
:
HI,
No As-Builts available however inspection and advice suggest the following;
• 100amp supply to the pole
• 415volt
• Currently fused at 80 amps.
Photos added today may provide more information.
Thanks
10/Nov/2025 10:08 AM
Question
:
Good Morning
Can you please confirm if you will be sending through the asbuilt drawings for this project?
Thank you,
Answered on 10/Nov/2025 12:42 PM
:
Hi,
Only available As-builts drawings has been provided this morning.
Thanks
10/Nov/2025 12:20 PM
Question
:
Where are the downpipes to be discharged? Existing shed has splash pads, are we allowing for this as well ?, or stormwater to discharge into existing water tanks for irrigation? No underground infrastructure shown on Cairns Mapping
Answered on 10/Nov/2025 12:46 PM
:
Hi,
As per the scope, stormwater is to be 'diverted to collection points in accordance with local council requirements'
This means that if discharge to ground via splash pads is permissible under council standards, that will be acceptable. Alternatively, discharge may be directed to an appropriate location.
It will be the contractor’s responsibility to confirm the compliant discharge method with the relevant authority.
Thank you
Updates made to this Request
29/Oct/2025 10:55 AM
Tenderers Interested in the Optional Site Meeting, Please RSVP by sending an email to Procurement@racingqueensland.com.au and advise number of personnel and a mobile number.
Site Meeting Details:
Date: (Thursday) 6th November 2025
Time: 11:00a.m.
Duration: 2 hours
Address: 585 – 619 Mulgrave Road, Woree QLD 4868
10/Nov/2025 10:47 AM
Please note: The following addenda have been recently added.
1. Added: (Addendum) 170990 CJC Irrigation Shed MSB Rev E.pdf
2. Added: (Addendum) 20251106_110958.jpg
3. Added: (Addendum) 20251106_111001.jpg
4. Added: (Addendum) 20251106_111002.jpg
5. Added: (Addendum) 20251106_111005.jpg
6. Added: (Addendum) 20251106_111009.jpg
7. Added: (Addendum) 20251106_115632.jpg
8. Added: (Addendum) 20251106_115639.jpg
9. Added: (Addendum) 20251106_115650.jpg
10. Added: (Addendum) 20251106_115654.jpg
11. Added: (Addendum) 20251106_115712.jpg
12. Added: (Addendum) Addendum 1 - RQ03814 - Cairns Machinery Shed - 10.11.2025.pdf
Please consider these addenda when responding.
10/Nov/2025 02:06 PM
Please note: The following addendum has been recently added.
1. Added: (Addendum) Addendum 2 - RQ03814 - Cairns Machinery Shed - 10.11.2025.pdf
Please consider this addendum when responding.