Tender Details
Access this Tender
Principal Contractor for RBWH Mental Health Stabilization Unit (MSHSU) and The Hub
Business Name
Metro North Hospital and Health Service
VP Reference #
VP523687
Buyers Reference #
MNHHS200297
Opens
Wednesday 02 September 2026
(E. Australia Standard Time)
Closes
Wednesday 14 October 2026 03:00 PM
(E. Australia Standard Time)
Supplier query cut-off
Sunday 11 October 2026 03:00 PM
(E. Australia Standard Time)
Expected decision
Wednesday 04 November 2026
(E. Australia Standard Time)
Buyer Details
Business Name
Metro North Hospital and Health Service
Location
330 Herston Rd
Herston, Queensland 4006
Australia
WebSite:
https://www.metronorth.health.qld.gov.au/
Business Info
Metro North Health enables people to deliver excellent patient-centred care and high quality health services. We focus on collaboration with healthcare partners and an investment in systems, engagement and culture, we connect people to deliver services to a population approaching 900,000, from north of the Brisbane River to north of Kilcoy.
Contact Name
Hassan Morshed
Position:
Principal Procurement & Contracts Officer
Primary phone:
+61 7 3542 3446
Mobile phone:
None Provided
Fax number:
None Provided
Email:
hassan.morshed@health.qld.gov.au
What the buyer is requesting
Details
Metro North Health (MNH) invites capable enterprises (regional, Queensland and others) to submit a Tender in response to Principal Contractor for RBWH Mental Health Stabilization Unit (MSHSU) and The Hub [MNHHS200297]
MNH will hold a site visits/briefing session on Thursday, 10 Sep 2026 at 10:00 AM and it is a mandatory requirement for the Tenderers to attend the site visit.
Tenderers need to share details of two (2) nominated persons of their company to: hassan.morshed@health.qld.gov.au by Wednesday, 09 Sep 2026 at 2:00 pm.
Attachments to this Request
Documents
22
Supplier lists selected
Lists
Construction & Operation
Categories selected
Categories
Construction & Operation
1: Building Construction Materials & Services
2: Demolition Services
3: Other Civil Construction Materials & Services
Regions of Service
Locations
Queensland
1: Brisbane
All Regions of Service locations are within Australia.
Information requested by others
11/Sep/2026 09:45 AM
Question
:
Good Morning,
Further to our site inspection yesterday, please see below RFI's:
Site Inspection
- We would like to arrange a site inspection for subcontractors to attend to view the existing site conditions. We would envisage that there would be approx. 10 to 15 subcontractor persons attending.
- During the site inspection we would need access to the following areas:
Switchboard Cupboards
Plantrooms
Medical Records
Comms Rooms
Plantrooms below SP2 for drainage requirements
General
- We would like to formally request and extension of time of 2 weeks to the tender period.
- The proposed works will require noisy works such as hammer drilling throughout construction. Given the location of the project, can you please advise a timeframe on when these noisy works can be completed on a daily basis.
- Please provide a floor plan of the proposed route from the loading dock to the goods lift and from the good lift to Lower Ground construction zone.
- Please provide the Hutchison site setup plans for the project they will be conducting around SP2 for our review and consideration in our methodology.
- Please confirm medical records working hours.
- Please provide a list of Base Building/Maintenance contractors for the following Trades. Please also confirm if they are nominated or alternative contractors can be used.
Electrical & Data
Mechanical
Fire
Security
Nurse Call
Medical Gas
BMS
Architectural
- Please provide details of the soft fall for the court yards proposed on the architectural documents. We are unable to locate this in the documentation.
- Please provide details of the courtyard finishes noted. We are unable to find these details in the documentation.
Powder coat to artists detail
Rendered blockwork to artists detail
Synthetic Surface to artist detail
Structural
- From our site inspection the existing Lower Ground external area has garden beds where the proposed new external court yards are being built. These existing garden beds infills are not shown on the structural plans to provide the new court yard surfaces. Please provide details.
- Blockwork wall shown on the architectural courtyard plans to encase the existing services against the existing retaining wall is not shown on the structural plans. Please provide details.
Answered on 11/Sep/2026 10:53 AM
:
Hi,
MNH will release Addendum 02 answering these RFIs.
Updates made to this Request
08/Sep/2026 08:53 AM
Please note: The following addendum has been recently added in response to the RFI received
1. Added: (Addendum) Addendum -01_08-09-2026.pdf
Please consider this addendum when responding.
15/Sep/2026 04:19 PM
Please note: The following addendum has been recently added.
1. Added: (Addendum) Addendum -02_15-09-2026.pdf
Please consider this addendum when responding.
22/Sep/2026 11:15 AM
Please note: The following attachments and addenda have been recently added.
1. Added: Addendum 2 - RFI 01.zip
2. Added: Addendum 2 - RFI 08.zip
3. Added: Addendum 2 - RFI 14.zip
4. Added: Addendum 2 - RFI 15.zip
5. Added: (Addendum) Addendum -03_22-09-2026.pdf to answer pending RFIs of Addendum 02
Please consider these attachments and addenda when responding.
22/Sep/2026 04:21 PM
Please note: The following addendum has been recently added.
1. Added: (Addendum) Addendum -04_22-09-2026.pdf
Please consider this addendum when responding.