Tender Details
26_143 - Warwick Distribution Centre and Reservoir Early Works - Construction
Business Name
Southern Downs Regional Council
VP Reference #
VP506528
Buyers Reference #
26_143
Opens
Monday 20 April 2026
(E. Australia Standard Time)
Closes
Monday 01 June 2026 02:00 PM
(E. Australia Standard Time)
CLOSED
Supplier query cut-off
Wednesday 27 May 2026 02:00 PM
(E. Australia Standard Time)
Expected decision
Monday 29 June 2026
(E. Australia Standard Time)
Buyer Details
Business Name
Southern Downs Regional Council
Location
64 Fitzroy St
Warwick, Queensland 4370
Australia
WebSite:
http://www.southerndowns.qld.gov.au/
Business Info
The Southern Downs Regional Council was formed on the 15th of March 2008 as an outcome of the Queensland Local Government Reform process. This new governing body encompasses the areas previously occupied by the Warwick and Stanthorpe Shire Councils.
Contact Details
The buyer has elected to have their personal and contact details hidden. These details will be revealed at the buyers discretion.
What the buyer is requesting
Details
Southern Downs Regional Council invites tenders from suitably qualified tenderers for Construction of Early Works (Pipelines in Road Reserves and connections to existing Distribution Network) for the Warwick Distribution Centre and Reservoir.
Supplier lists selected
Lists
Construction & Operation
Categories selected
Categories
Construction & Operation
1: Building Construction Materials & Services
2: Other Civil Construction Materials & Services
3: Pipes & Fittings Services
4: Underground Services
Regions of Service
Locations
Queensland
1: Darling Downs
All Regions of Service locations are within Australia.
Information requested by others
27/Apr/2026 02:49 PM
Question
:
Is there a site visit for these works?
Answered on 28/Apr/2026 09:33 AM
:
There is a site briefing. The details are contained within the 26_143 - Request for Tender document.
05/May/2026 04:59 PM
Question
:
Hi
Could council please clarify the size of DICL pipe that comes from the future Distribution Centre and connects to Detail 3 at the Glen Rd South watermain? There appears to be a reducer shown in Detail 3 and then the pipework from there on is DN200 and DN150. Thank you
Answered on 06/May/2026 12:20 PM
:
Please see Addendum 1. The 26_143 - Pipe layout drawing from Distribution Centre drawing provided shows detail of all pipework out of the proposed distribution centre.
06/May/2026 09:43 AM
Question
:
Hi
Would council please be able to provide a copy of SDRC STD DRG W-0041 as referenced on the drawings for the thrust block detail? Thank you
Answered on 06/May/2026 12:21 PM
:
This is in error. SDRC does not have standard drawings. It should be IPWEAQ Standard Drawing – Water Main
Thrust Block Details IPWEAQ W-0041. Please see Addendum 1, this drawing has been provided.
06/May/2026 09:44 AM
Question
:
Hi
Would council permit pressure testing against valves? Thank you
Answered on 06/May/2026 12:21 PM
:
Please provide details of proposed testing.
07/May/2026 04:51 PM
Question
:
Hi,
We would like to request an additional site inspection so we can participate in the upcoming tender. Would this be possible? Alternatively, can we submit a tender without attending the site meeting on the 5th of May.
Thanks
Answered on 15/May/2026 12:06 PM
:
Please see Addendum 3.
26/May/2026 01:42 PM
Question
:
Hi
Glen Road – South water main shows the 200DICL leaving the limit of Distribution Centre Works and Early Works Boundary for approximately 2.4m then as per detail 3 reducing to a 150DICL components to go around existing services and remaining at 150 thereafter.
Yet the drawing says it is a 200 DICL Across Tooth St and down the Eastern side of Tooth St.
With the line Running down the West side of Tooth St being 150DICL.
Could you please clarify the details for this area and if it needs another Reducer to upsize back to 200DICL after the TEE for the West side 150DICL
Answered on 26/May/2026 03:45 PM
:
There is an error with this detail for the Glen Road South line. The arrangement should be
200x200x200 FL-FL-FL DI TEE With a 200-150 reducer to
150 FL-SO DI CONNECTOR
Updates made to this Request
30/Apr/2026 04:04 PM
Contractors are reminded of the mandatory site briefing for this Request for Tender. If you wish to submit a tender you must attend the site briefing.
Please RSVP your intention to attend by emailing procurement@sdrc.qld.gov.au by 12:00pm tomorrow - 01/05/2026.
06/May/2026 12:18 PM
Please note: The following addenda have been recently added.
1. Added: (Addendum) 26_143 - Addendum 1.pdf
2. Added: (Addendum) 26_143 - IPWEAQ Standard Drawing – Water Main Thrust Block Details - W-0041.pdf
3. Added: (Addendum) 26_143 - Pipe layout drawing from Distribution Centre.pdf
Please consider these addenda when responding.
08/May/2026 12:46 PM
Please note: The following addenda have been recently added.
1. Added: (Addendum) 26_143 - Addendum 2.pdf
2. Added: (Addendum) WRtM-CV-0041 [C].pdf
3. Added: (Addendum) WRtM-CV-0060 [C].pdf
Please consider these addenda when responding.
15/May/2026 12:06 PM
Please note: The following addendum has been recently added.
1. Added: (Addendum) 26_143 - Addendum 3.pdf
Please consider this addendum when responding.